Introduction:
|
AD2091 the device to control signal of AD1024 high speed data line into the control code for AD receiver (Manchester), provides up to 64 independent buffer control code output, divided into 4 groups, each group of 16. Each group can control 64 camerasite. Cascade multiple devices, can control up to 1024 cameras, each output availablecable to transmit 5000 feet (double shielded wire, recommend Belden8760 orequivalent 18AWG- America gauge). Can connect up to 5 receivers in the terminationcode transmission line right. If you need more than 64 independent control code output, through high-speed data line cascaded multiple code / distributor. A RS-232 output and selectable baud rate, can be used to control RS-232 receiver of AD company. The equipment with the old AD receiver when used together, the internalfilter can filter transmission of new AD system control signal.
● input: high speed data, BNC socket, link, 75.
● output: control code, 64 screw terminal connectors, 120 ohm, or a RS-232 type 8 pin assembly connectors.
● voltage: 120V/60Hz (behind the model plus X, 230V/50Hz)
● power: 8W (nominal)
● installation: can be installed on the machine frame (universal frame) or on the desktop.
● size: 89 (high) x 432 (wide) x 203 (L) mm
● weight: 3.1Kg
|